Material: Cast Iron
Structure: Single-stage Pump
Assembly: Booster Pump
Power: Hydraulic
Start Up: Start Pump
Type: Diesel Pump
Customization:

Contact Supplier

Diamond Member Since 2014

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
KYBC
Application
Clarified Water Pump
Industry
Agricultural Irrigation Pump
Media
Water
Performance
No Leakage Pump
Theory
Centrifugal Pump
Model
Kybc Diesel Pump
E Power
Diesel Engine Driven, ≤110kw
Pressure
0.3-2.5MPa
Environment Tem
5centegrates Degree~40centegrates Degree
Transport Package
Standard Export Packing or According to Customers′
Trademark
Kaiyuan
Origin
Shanghai, China
Production Capacity
1000PCS/Year

Product Description


0UTLINE:
A late-model fire-fighting equipment, XBC diesel driven engine fire-fighting water pump group series with high pressure are developed successfully, strictly complying with national standard-GB6245 2006 "Performance requirement and testing method of fire fighting pumps" and with NEPA20 "Installation of centrifugal fire-fighting pumps".
 
Classified by fitted ones (single stage single suction type, single, this equipment can fall into three sub-categories: XBC-IS, XBC-S and XBC-D The equipment are widely used in many occasions.
 
Related diesel engines are classical domestic or imported ones, which have features of stable starting, high capacity compact structure, easy maintenance and high automation, thus, they are fire-protection equipments with advanced and dependable performance.
 
 
STRUCTURE & FUNCTIONS:
 
 
X61 35, 12V1 35, 4102 4105, 61 02, 4100 495 etc diesel engines series provide power for our pumps. Fire-fighting pump unit consist of fire-fighting pump and these diesel engines (also work with clutches), which is attached to high elastic clutches, besides diesel tank, radiation water tank, blower, control screen (for the automation unit) etc components.
 
Being the auto-control unit,a separate diesel engine auto-control cabinet (Programmable) carries out the system's automatic starting, performance, auto-switching (the motor pump unit is switched to the diesel engine pump one or the diesel engine pump unit to another unit), auto-protection (warning and stopping protection for the diesel engine's over-speed, lower oil pressure, high water temperature, three times of failures in starting, low voltage of accumulator warning etc functions) and also can be connected to fire fighting centers of users or the auto-warning device of fire with the purpose of remote monitoring.
 
In order To keep the unit working normally below 5°C, it can be fitted with an AC220V water-cooling pre-heater.
 
The diesel engine fire-fighting pump group can be formed as an automatic fire fighting ware-supply system(see tabel1), with an electric pump and pressure maintaining one, as you can read "Diesel engine control system". The equipment can be jointly controlled with a fire-fighting center.
 
There are two water inlet ways: self-pouring and suction-up. The former is preferred because of fire-protection standard. If our clients specially ask for suction-up ones, they are required to point out so our company supply automatic vacuum water leading device. However, the change of dimension of the pump unit is necessary.
 
 
SYSTEM STRUCTURE & PRINCIPLE:
 
 Electric fire fighting water supply system is generally Consist of a pressure stabilizing pump, electric pump (corn pump) and automatic diesel engine pump (spare one) and its working principle manifest itself: usually the pipe network's pressure maintain between P1 (low one) and P2f (high one) The stabilizing pump starts when the pressure below P1 and stops after it rises to P2. It lowers slowly from P2 to P1 due to the leakage of the network, the stabilizing pump starts again to maintain between P1 and P2. When the amount of water is increased, the stabilizing pump could not keep the pressure at P1 and it quickly fall to P3 the electric pump starts and the pressure rises to PW (well) to meet with the demand for fire-fighting water. In case of power-off or a failure in the electric pump operation, the pressure goes on lowering from P3 to P4, the diesel engine pump automatically starts to operate, and then it rises to PW and provides water. The electric pump or diesel engine pump has to stop if any man-made judgment, if it comes to large leakage from the pipe network, it is necessary to add pressure stabilizing tanks or make the pressure stabilizing pump normally opened so as to avoid frequent starting
 
(1) KYCK BH series semi-auto diesel engine fire-fighting pump control equipment.
 
This electric control cabinet (box) has both manual and semi-auto control function and can display the oil pressure, water temperature of the diesel engine, the charging current of the accumulator and warning at too low level of the oil tank. Automatically start the diesel engine pump in case of a failure in the electric pump operation or power-off under the fire-alarm status and remotely start the diesel engine pump. This control mode is used when the power of the diesel engine is below 110KW.
 
(2) KYCK BZ series fully-auto diesel engine fire-fighting pump control equipment.
 
This electric control cabinet (box) has both manual and fully-auto control function and can display the diesel engine's oil pressure and oil temperature and water temperature and emergency warning, reveal of accumulator's charging current, warn at an abnormal condition and when level of the oil in tank is too low .as well as at an extra high speed or low speed for stopping and when three starting failures warning. It can be automatically charging when battery's voltage is too low, which could be connected to a fire-fighting center or an automatic fire-alarm device to conduct the remote linkage control. As a multi-pumps unit, it can realize units switch and regular inspection of fire-fighting pump and constant pressure on power frequency (such function should be added in our clients' contract). This control way adapt to diesel engine of above 110kw.
 
SCOPE OF SUPPLY:
We supply diesel engine (including oil tank and accumulator) fire-fighting pump, high elastic clutch and their pedestal and electric control cabinet for control. Auto- fire -fighting water supply system formed by electric fire -fighting pump pressure and stabilizing pump etc. made in this company in fact are composed of the electric fire fighting pump, pressure stabilizing pump group and pressure controller. The joint cables for control cabinet and pump unit are not our business.
 
 
WAY OF GENERATOR COOLING:
The cooling system of the oil engine supplied by this company, is generally closed cycle and heat exchange cool the generator when blower in radiator tank blow a wind across the generator's surface. Please indicate your order if you want an opened cycle of cooling (we conduct the cooling of generator through way of water pump and the heat exchanger relied on inside cycle water in diesel engine
 
POWER LOSS 0F DIESEL ENGINE:
Under the non-normal running of the equipment the power loss of the diesel engine: DNe=Kne (Ne is the rated power). Therefore, in order to ensure it run normally, when you chose suitable diesel engine you should take power loss into consideration under the non-normal ambient condition, which is matched with pump, see table K-value as a reference.
 
VOLUME OF OIL TANK:
The oil tank used for the diesel engine of a power below 60kW can be directly mounted on the unit while the one for the diesel engine of a power over 80kW can be separated from the unit. The following listed oil tank volumes can ensure the diesel engine fire-fighting pump groups of different powers can normally work for 6 hours under the rated working conditions.
 
INSTALLATION & ATTENTION:
 
1. About 1m passage and space should be left on both sides of the unit and in the front of both cooling blower and water tank, with the purpose of better radiation, equipment servicing and maintenance. The height of the machine room should be depended on the equipment's height and the lifting apparatus general height is 3-5m.  
 
2. The unit is generally concrete structure. Its round dimensions equal the four peripheries of the unit feet plus 150-200mm and depth equal 400-600mm. The foot bolt stretches out of the bolt hole by a height about 2 times the diameter of the bolt and a notch is set in the middle of the basis and grooves are set round for dirt water oil discharge .The concrete foundation must be solid and flat, when the unit are fixed on it, foundation bolts keep gasket between unit bottom seat and basis, the washers must be flat. Put a leveler on the pump shaft to ensure correction of driving shaft. When bottom seat and pump are fixed well, pour cement around the foot bolt, then after the cement gets hardened, evenly tighten the foot bolt, still pour cement on the bottom seat to make sure the unit are stable and solid, finally correct the concentricity between the fire-fighting pump and the diesel engine's driving shafts, and the outer circles of the two clutches must be linear and share the same gap.
 
3. To ensure good ventilation in the machine room, the temperature should not be over 40°C and enough venting holes must be set up. When natural ventilation is not sufficient for the venting and radiating requirement, Intake ventilators near the venting holes should be fixed to strength the ventilating performance.
 
4. To ensure a fresh air in the machine room, it is necessary to prevent lots of heat from radiating inside and lower the noise. Wrap the exhaust pipe of the diesel engine with asbestos, extend it outdoor and mount a rainproof device on it or mount it 30°downward and a silencer. The number of the elbow should be as less as possible and the bent radius of the elbow should be over 2.5 times the outer diameter of the exhaust pipe, take it into consideration for the support of the pipe to lower vibration and prevent its extra force on diesel engine.
 
5. When mounting both inlet and outlet pipes of the fire-fighting pump do not let their weight loading on the pump so as to prevent it against damage and its normal performance. The inlet pipe should be as short and straight as possible when it is a self-pouring one. lt must be mounted upward slightly towards the pump to make sure no air exists inside of the pipe. A filter screen and flexible connector should be mounted on the inlet and a flexible connector, check valve and gate valve on the outlet.
 
6. It is not allowed to mount the control cabinet in front of the diesel engine's radiator, otherwise the electric components inside of the cabinet would be affected and could not work normally and it should be mounted on both sides of the unit or nearby so as to get a convenient operation. The wiring between both control cabinet and diesel engine should not be more than 35m.
 
 
FLANGE DIMENTION:
 
  Kybc Hot Sell High Effeciency Easy Maintenance Diesel Agricutural Pump Kybc Hot Sell High Effeciency Easy Maintenance Diesel Agricutural Pump
 
 
PARAMETERS:
 
 
 
START, STOP & RUNNING:
 
1 Start: Before starting ensure the correction of pump rotating direction and non-water pipe network. Inlet valve show sign of N.O while outlet one of N.C. then start the fire-fighting pump .when the pump run stably, gradually open the outlet valve and adjust it to the work condition point for the pump running. The outlet valve is the sign of N.O when the network is filled with water at ordinary times
 
 
 
2. Run: When the pump gets a normal run, check the shaft seal and the bearing to see how it works. The leakage frequency for the stuffing seal should be not more than 3dot/min The bearing' s temperature should not be over 75°C, and its temperature variation should be less than 35°C. Stop running for a checking case of an abnormal sound during working.
Kybc Hot Sell High Effeciency Easy Maintenance Diesel Agricutural Pump Kybc Hot Sell High Effeciency Easy Maintenance Diesel Agricutural Pump Kybc Hot Sell High Effeciency Easy Maintenance Diesel Agricutural Pump

Send your message to this supplier

*From:
*To:
avatar Miss Anna Cho
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2014

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Year of Establishment
2002-06-18
Registered Capital
29.56 Million USD