• Kaiyuan Kyk Pump Pressure Control Panel
  • Kaiyuan Kyk Pump Pressure Control Panel
  • Kaiyuan Kyk Pump Pressure Control Panel
  • Kaiyuan Kyk Pump Pressure Control Panel
  • Kaiyuan Kyk Pump Pressure Control Panel
  • Kaiyuan Kyk Pump Pressure Control Panel

Kaiyuan Kyk Pump Pressure Control Panel

Task: Program
Structure: Closed-Loop
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: RoHS, CCC, ISO: 9001
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
KYK-P
Condition
New
Customized
Customized
Material
Aluminum Alloy
Components
Contactor, Breaker, Relay, etc.
Protection Class
IP 23 (for Higher Protection Class, Please Advise)
Voltage
220V/380V/460V
Lead Time
Generally Within 15 Days
Control Mode
Direct/Star Delta/Soft/Autotransformer/VSD
Standard
China National GB Standard
Insulation Class
F
Additional Function 1
Timed Start-Stop; Dual Power.
Additional Function 2
Remote Control Interface
Additional Function 3
Building Automation Interface
Main Pump Standby Pump Switching Mode
Manual;Timing Switch ; Alternating Switchove
Start-up Mode 1
Direct Start; Star Delta Start;
Start-up Mode 2
Self-Coupling Step-Down Starting; Soft Start
Transport Package
Plywood Case
Specification
according to specification
Trademark
KAIYUAN/OEM
Origin
China
HS Code
8537109090
Production Capacity
2000 Sets / Month

Product Description

Product Description

>>> Product Overview
Kaiyuan Kyk Pump Pressure Control Panel are mainly used in household water supply, fire fighting pressure stabilization, air-conditioning water pump system and production process water, etc. Generally, electric contact pressure gauges and pressure switches are equipped to set upper and lower limit of working pressure. It starts when pipe network's pressure is lower than lower limit, and stops when pipe network's pressure reaches upper limit. Pressure range between upper and lower limit cannot be too little. Otherwise, equipments will be caused to start & stop frequently, affect motor system's performance and cause motor faults. Pressure stabilizing measures are commonly taken to reduce pressure fluctuation such as pressure tank in order to ensure the system's normal operation. 

Kaiyuan Kyk Pump Pressure Control PanelKaiyuan Kyk Pump Pressure Control Panel


>>> FUNCTION DESCRIPTION
Water Pump Working Mode
1. One main and one standby:
When controlling 1 and 2 pumps, it can work in two states '1 main and 2 standby' or '2 main and 1 standby'. When the main pump breaks down, the standby pump will start to work automatically. Start manually by panel operation button. If the user requires to use both pumps, it is not necessarily to equip the standby pump.

2. Two mains and one standby:
When controlling 1, 2 and 3 pumps, it can work in three states '1, 2 main and 3 standby' or '2, 3 main and 1 standby' or '1, 3 main and 2 standby'. When the main pump breaks down, the standby pump will start to work automatically. Start manually by panel operation button. If the user requires to use all pumps, it is not necessarily to equip the standby pumps.

3. Three mains and one standby:
When controlling 1, 2, 3 and 4 pumps, it can work in four states '1, 2, 3 main and 4 standby' or '2, 3, 4 main and 1 standby' or '1, 3, 4 main and 2 standby' or '1, 2, 4 main and 3 standby'. When the main pump breaks down, the standby pump will start to work automatically. Start manually by panel operation button. If the user requires to use all pumps, it is not necessarily to equip the standby pumps.

Main Pump And Standby Pump Switch Mode
1. Manual switch:
Main pump and standby pump are switched manually. When the main pump has faults, the standby pump will start to work automatically.
2. Ac automatic alternative switch:
It is proper for the occasion where main pump and standby pump need to work alternatively. Once started, the main pump and standby pump will alternate one time. This type also has a function that the standby pump switches automatically if there is a fault.
3. As timing switch:
It is proper for the occasion where the pumps work frequently, which makes each pump's working time more average and prevents one pump's long time using and huge losses. It is switched at an interval time.

Start-up Mode
1. Direct start:
Full-voltage starting, full-voltage operation, large starting current.
2. Autotransformer start:
Voltage and current will be reduced by autotransformer when starting, and will be restored to rated voltage when operating.
3. Soft start:
Pumps are started by electric soft starter, there is no contact diverter during the start process, and voltage and current will rise smoothly, which will not make huge impact on power grid and pipe networks.

Additional Function
1. Timing start-stop:
Pumps can starts and stops at a predetermined time according to the time which is set by clock operated switches in the control panel.
2. Remote interface:
Electric control panel is equipped with remote monitoring terminals and can convey pumps' working condition to duty room in remote distance in order to be monitored.
3. BA interface:
Electric control panel is equipped with building automatic remote monitoring terminals, showing equipments' working condition and enabling start-stop controls.
4. Dual power:
Electric control panel is connected with dual power supply, which be switched automatically and manually.

WORKING ENVIRONMENT
1. mains voltage fluctuation:≤±10%;
2. surrounding environment temperature:-10-±40ºC(non-frozen);
3. air relative humidity:20%-60%(without condensation);
4. place without explosive danger;
5. place without conductive dust and gas which can corrode mental and destruct insulation;
6. vibration: <5.9m/s2( 0.6G), inclination:≤ 5°;
7. absolute altitude:≤1000m.


>>> PERFORMANCE CHARACTERISTICS
1. Simple circuit design and reasonable structure, which is convenient for faults analysis.
2. There are manual, automatic and remote control function, which can ensure the equipments' safe and continuous operation.
3. Excellent performance, flexible control methods, strong resistance to interference, steady and safe working condition.
4. Protection function: motor overload, short circuit, phase losses, pump casing leakage, motor stator overheat, safe usage, simple maintenance.
5. Programmed control, several control modes according to users' requirements such as several pumps' automatic alternative operation and timing start & stop.
6. High-power pumps can be started smoothly by frequency converter or smart soft starter.


>>> APPLICATION SPECIFICATION
It's one of the common control modes for household water supply. In accordance with different control requirements and control accuracy, electric contact pressure gauges and pressure switches are applied to collecting pressure signals of water supply pipe networks and controlling pumps' start & stop, generally equipped with pressure tanks. 

According to the pressure magnitude of circulating water pipe network, switch signals are output by pressure inspection, pumps' start & stop is controlled, the pressure implemented which loses from circulating water pipe networks so that it can meet users' requirements. 

1. Pressure feed water control
2. Pressure supplement water control
3. Fire-fighting steady pressure control.
 
 

>>>HUMAN-COMPUTER INTERFACE
There are two kinds of configuration industrial human-computer interface. 
1. Text display with simple function (Chinese interface) It can be set up some basic parameters and displays as picture and text forms.
2. Touching-type industrial figure display (touch screen)
There is a 32bit RISC CPU so that the operating speed is fast. Plenty of screenshots can be set up. The system state isdisplayed in the form of image and text combined. The interface communicates via touch screen, PLC (programmable logic controller) and frequency converter. Parameters such as working pressure and flow are set up via the touch screen. The touch screen also displays information on site such as each pump's working condition, real-time pressure, frequency and breakdown, etc. It's easy and simple to handle. The function of replacing control panel improves reliability of the system.


>>>NETWORK COMMUNICATION
Currently, many pumping stations, water plants and enterprises has formed an international popular industrial Ethernet standard based on TCP/IP, which is applied to remote monitoring operation condition of systems such as pump sets and electric. Field control system has programmable controllers and communication expandable modules and is connected to monitoring network via field bus. It has standard communication interface such as serial RS232/RS485, supports Ethernet and TCP/IP field bus base protocol and can remote control and monitor equipments. 


Currently, many pumping stations, water plants and enterprises has formed an international popular industrial Ethernet standard based on TCP/IP, which is applied to remote monitoring operation condition of systems such as pump sets and electric. Field control system has programmable controllers and communication expandable modules and is connected to monitoring network via field bus. It has standard communication interface such as serial RS232/RS485, supports Ethernet and TCP/IP field bus base protocol and can remote control and monitor equipments. 

Kaiyuan Kyk Pump Pressure Control Panel
Kaiyuan Kyk Pump Pressure Control Panel
>>> Company Information & Advantages

1. Delivery time:
  • We put your order into our tight production schedule, keep our client informed about production process, ensure your punctual delivery time.
  • Shipping notice/ insurance to you as soon as your order is shipped.

2. After sales service:

  • After receiving the goods, We accept ur feedback at first time.
  • We could provide installation guide, if you have need, we could give you global service.

3. Professional sales:

  • We value every inquiry sent to us and ensure quick competitive offer.
  • We cooperate with customer to bid tenders, and  provide all necessory document.
  • We are a sales team, with all techinical support from engineer team.

Shanghai Kaiyuan Pump have many global clients, we offer professional service to them.  With the aim of "to establish a close strategic partnership and develop together with customers".  we will work whole heartedly to improve our products and service. We will also pledge to work jointly with businese partners to elevate our cooperation to a higher level and share success with together with our customers. We are looking forward to establishing relationships with you in the near future.   
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2014

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Year of Establishment
2002-06-18
Registered Capital
29.56 Million USD